Recessed Door Sensor, Gen 5

Submitted By Brett E.

Manufacturer: Aeon Labs
Model #: ZW089-A

Compatible with Axial

Door sensor works correctly with ICHA. Natively reports battery (%). In order to auto configure, press button for 6 seconds to wake-up. Unit will sleep after 10 seconds.

Parameters:

1= Sensor Binary Report Send (Default 0) 0=Send on open contact 1=Send on closed contact
3= Sensor Basic Set Send (Default 0) 0=Send on open contact 1=Send on close contact.
101= Low Battery Checking (Default 0) 0= Disabled 1=Enabled
111= Low Battery Checking Interval (Default 01 52 70 (4 minutes). This is a 4 byte hex value.
121=Command Set (Default 0x00000100 (Basic Set) This is a 4 byte hex value.
252=Lock / Unlock all config parameters (Default 0) 0=Unlocked 1=Locked

COMMENTS

Login to Comment