4-in-1 Multi Sensor

Submitted By Giancarlo D.

Manufacturer: Philio
Model #: PST02-1A

Compatible with Axial

This device requires InControl Version 4.0.5593 or later

INCLUSION
- Add Device
- Press TMP button 3 times in one second

DEVICE TYPE
- Set as MultiLevelSensor

PROPERTIES
- Flag this
- Audit Node (for testing than can be removed)
- Queue Command Utile Wakeup

AUTO CONFIG
- Go Offline/Online
- Auto Configuration
- Success! Manuf Id is 316. Prod Id is 12

PARAMETERS
- look at pepper1 (http://www.pepper1.net/zwavedb/device/575)
- 1 to 0 (default)
- 3 to 80 (default)
- 4 to 99 (default)
- 5 to 8 (cofig temperature reported in Celsius)
- 6 to 4 (default)
- 7 to 22 (config the door contact sensor and the motion sensor to each send their own message so that can be differentiated between whether motion was detected or the door was opened/closed)
- 8 to 3 (default)
- 9 to 4 (default)
- 10 to 12 (default)
- 11 to 12 (default)
- 12 to 12 (default)
- 13 to 12 (default)
- 20 to 30 (default)
- 21 to 1 (default)
- 22 to 0 (default)

PARMETERS BIT EXPLAIN
- example parm 7
Bit: 7 6 5 4 3 2 1 0
0 0 0 1 0 1 0 0
Value 128 64 32 16 8 4 2 1
-------------------------------------
0 + 0 + 0 +16 + 0 + 4 + 2 + 0 = 22 <-- Value to insert

- example parm 5
Bit: 7 6 5 4 3 2 1 0
0 0 0 0 1 0 0 0
Value 128 64 32 16 8 4 2 1
-------------------------------------
0 + 0 + 0 + 0 + 8 + 0 + 0 + 0 = 8 <-- Value to insert

END
Now you can see and use the 4 subdevice in the right (Luminance, Motion, Temperature, Door/Windows)